ELVIAL SL50 HI² CLASSIC

IDENTITY
DesignLinear Design [LD]
Sash Depth1 15/16″
Visible Height(Infloor Edition)2 8/16″ || 3 2/16″
Visible Height(Standard Edition)4 5/16″ || 4 5/16″ || 4 15/16″ || 3 11/16″
Meeting Style Construction Width5 16/16″ || 7 4/16″
Middle Mullion Width(Fixed T)1 14/16″ || 3 14/16″
PROPERTIES
Max Sash Height137 13/16″
Max Sash Width118 2/16″
Max Sash Weight881.85 lbs
Max Glass thickness1 5/16″ || 1 7/16″
PERFORMANCE
Uf Value(≥) EN ISO 10077-21.34 BTU/(hr·ft·°F)
Air Permeability EN 12207Class 4
Watertightness EN 12208Class E900
Resistance to Wind Load EN 12210Class B2
Sound Reduction ΕΝ 10140-243db
Brochures & More
Product Leaflet
Manuals
Order Manual
Available only in Metric
Fabrication Manual
Available only in Metric
Certificates Catalog
Certificates Catalog
EPD
2-SASH SUCCESSIVE CONSTRUCTIONS
REVIT File(Classic Edition)
Instructions(Classic Edition)
REVIT File(Flat Edition)
Instructions(Flat Edition)
2-SASH SUCCESSIVE CONSTRUCTIONS WITH FLYSCREEN
REVIT File(Classic Edition)
Instructions(Classic Edition)
REVIT File(Flat Edition)
Instructions(Flat Edition)
3-SASH SUCCESSIVE CONSTRUCTIONS
REVIT File(Classic Edition)
Instructions(Classic Edition)
REVIT File(Flat Edition)
Instructions(Flat Edition)
4-SASH SUCCESSIVE CONSTRUCTIONS WITH MEETING STILE
REVIT File(Classic Edition)
Instructions(Classic Edition)
REVIT File(Flat Edition)
Instructions(Flat Edition)
4-SASH SUCCESSIVE CONSTRUCTIONS WITH MEETING STILE AND FLYSCREEN
REVIT File(Classic Edition)
Instructions(Classic Edition)
REVIT File(Flat Edition)
Instructions(Flat Edition)
6-SASH SUCCESSIVE CONSTRUCTIONS WITH MEETING STILE
REVIT File(Classic Edition)
Instructions(Classic Edition)
REVIT File(Flat Edition)
Instructions(Flat Edition)
HOTEL EDITION SUCCESSIVE CONSTRUCTIONS
REVIT File(Classic Edition)

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Company
  • Design
  • Hardware
  • Hardware
  • Air Permeability EN 12207
  • Resistance to Wind Load EN 12210
  • Watertightness EN 12208
  • Anti-Burglar Resistance
  • Sound Reduction EN 10140-2
  • Max Glass Thickness (mm)
  • Thermal Insulation Uf (W/mK)
  • Thermal Break (mm)
  • System Depth(mm)
  • Sash Depth (mm)
  • Frame Depth (mm)
  • Min Face Height [Frame-Sash] (mm)
  • Min Face Height [Threshold-Sash] (mm)
  • Min Face Width [Middle Mullion] (mm)
  • Max Sash Weight (kg)
  • Max Sash Height (mm)
  • Max Sash Width (mm)
  • Visible Height Infloor Edition (mm)
  • Visible Height Standard Edition (mm)
  • Meeting Stile Construction Width (mm)
  • Middle Mullion Width Successive (mm)
  • Middle Mullion Width Fixed T (mm)
Compare
Compare ×
Let's Compare! Continue shopping
Scroll to Top