ELVIAL SL50 HI² CLASSIC

IDENTITY
DesignLinear Design [LD]
Sash Depth50 mm
Visible Height(Infloor Edition)64 mm || 80 mm
Visible Height(Standard Edition)109 mm || 110 mm || 125 mm || 94 mm
Meeting Style Construction Width152 mm || 184 mm
Middle Mullion Width(Fixed T)48 mm || 98 mm
PROPERTIES
Max Sash Height3500 mm
Max Sash Width3000 mm
Max Sash Weight400 kg
Max Glass thickness34 mm || 36 mm
PERFORMANCE
Uf Value(≥) EN ISO 10077-22.32 W/mK
Air Permeability EN 12207Class 4
Watertightness EN 12208Class E900
Resistance to Wind Load EN 12210Class B2
Sound Reduction ΕΝ 10140-243db
Brochures & More
Product Leaflet
Manuals
Order Manual
Fabrication Manual
Certificates Catalog
Certificates Catalog
EPD
2-SASH SUCCESSIVE CONSTRUCTIONS
REVIT File(Classic Edition)
Instructions(Classic Edition)
REVIT File(Flat Edition)
Instructions(Flat Edition)
2-SASH SUCCESSIVE CONSTRUCTIONS WITH FLYSCREEN
REVIT File(Classic Edition)
Instructions(Classic Edition)
REVIT File(Flat Edition)
Instructions(Flat Edition)
3-SASH SUCCESSIVE CONSTRUCTIONS
REVIT File(Classic Edition)
Instructions(Classic Edition)
REVIT File(Flat Edition)
Instructions(Flat Edition)
4-SASH SUCCESSIVE CONSTRUCTIONS WITH MEETING STILE
REVIT File(Classic Edition)
Instructions(Classic Edition)
REVIT File(Flat Edition)
Instructions(Flat Edition)
4-SASH SUCCESSIVE CONSTRUCTIONS WITH MEETING STILE AND FLYSCREEN
REVIT File(Classic Edition)
Instructions(Classic Edition)
REVIT File(Flat Edition)
Instructions(Flat Edition)
6-SASH SUCCESSIVE CONSTRUCTIONS WITH MEETING STILE
REVIT File(Classic Edition)
Instructions(Classic Edition)
REVIT File(Flat Edition)
Instructions(Flat Edition)
HOTEL EDITION SUCCESSIVE CONSTRUCTIONS
REVIT File(Classic Edition)

You may also like…

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Company
  • Design
  • Hardware
  • Hardware
  • Air Permeability EN 12207
  • Resistance to Wind Load EN 12210
  • Watertightness EN 12208
  • Anti-Burglar Resistance
  • Sound Reduction EN 10140-2
  • Max Glass Thickness (mm)
  • Thermal Insulation Uf (W/mK)
  • Thermal Break (mm)
  • System Depth(mm)
  • Sash Depth (mm)
  • Frame Depth (mm)
  • Min Face Height [Frame-Sash] (mm)
  • Min Face Height [Threshold-Sash] (mm)
  • Min Face Width [Middle Mullion] (mm)
  • Max Sash Weight (kg)
  • Max Sash Height (mm)
  • Max Sash Width (mm)
  • Visible Height Infloor Edition (mm)
  • Visible Height Standard Edition (mm)
  • Meeting Stile Construction Width (mm)
  • Middle Mullion Width Successive (mm)
  • Middle Mullion Width Fixed T (mm)
Compare
Compare ×
Let's Compare! Continue shopping
Scroll to Top